力士樂Rexroth伺服驅(qū)動(dòng)器各類故障維修:E825 Overvoltage Error過電壓錯(cuò)誤。REXROTH力士樂伺服驅(qū)動(dòng)器維修,REXROTH力士樂伺服電源維修,REXROTH力士樂伺服控制器維修,博世力士樂電源模塊維修,博世力士樂驅(qū)動(dòng)器維修。
Cause:原因:
1. The mechanical system energy reflected via the motor was so large for a moment that it could not be completely converted to heat by the bleeder.
通過電機(jī)反射的機(jī)械系統(tǒng)能量一度過大,以至于無法通過放氣器完全轉(zhuǎn)化為熱量。
As a result, the DC Bus voltage rose above the maximum allowable value.
結(jié)果,直流母線電壓上升到最大允許值以上。
The motor is then switched to torque free operation.
然后將電機(jī)切換到無扭矩操作。
If the DC Bus voltage falls below the maximum allowable value, the controller will be turned on again.
如果直流母線電壓低于最大允許值,控制器將再次接通。
2. DC Bus voltage is too high
直流母線電壓過高
Remedy:補(bǔ)救措施:
1Reduce the acceleration value and check the drive controller layout if necessary.如有必要,降低加速度值并檢查驅(qū)動(dòng)器控制器布局。
Install an auxiliary bleeder, if necessary.
如有必要,安裝輔助放氣閥。
2 Check the supply voltage, if necessary.
如有必要,檢查電源電壓。