baumullre鮑米勒驅(qū)動器開不了機719故障代碼修理維護(hù)

發(fā)布者:hp    來源:上海仰光電子科技有限公司     發(fā)布時間:2023-12-5

baumullre鮑米勒驅(qū)動器開不了機719故障代碼修理維護(hù)
鮑米勒驅(qū)動器開不了機維修
719:Timeout during motor identification電機識別超時。

Error during identification of motor parameters. The maximum permitted phase voltage (= 80 V) was exceeded during the resistance measurement.識別電機參數(shù)時出錯。在電阻測量過程中,超過了每個允許相的最大電壓(=80V)。

Possible cause: 原因:
Incorrect motor nominal current setting in Parameter 107.09.
參數(shù)107.09中的電機標(biāo)稱電流設(shè)置不正確。
Effect: Output voltage set to ZERO to protect the motor. An additional drive block occurs with standard error response.

效果:輸出電壓設(shè)置為零,以保護(hù)電機。附加的驅(qū)動器塊出現(xiàn)標(biāo)準(zhǔn)錯誤響應(yīng)。

Resetting after error elimination: 錯誤消除后重置:
Error reset is possible. Timeout (45 seconds) with R measurement with motor parameter identification, such as due to error during current / voltage measurement or normalization or limit value.錯誤重置是可能的。電機參數(shù)識別的R測量超時(45秒),例如由于電流/電壓測量或標(biāo)準(zhǔn)化或限值過程中的錯誤。

鮑米勒驅(qū)動器常見故障修理維護(hù):
baumullre鮑米勒BM4434-SI1-01242-0311-7012維修,
羅蘭BAUMULLER(鮑米勒) BUM617-12/18-31羅蘭印刷機墨轆驅(qū)動器維修,
BAUMULLER苞米勒鮑米勒伺服驅(qū)動器BUG3-35-31-B-010 BUG3-35維修,
BAUMULLER鮑米勒BUS 6V主板BUS6-VC-AC-0067維修,
3.9511D BAUMULLER鮑米勒板卡鮑米勒伺服鮑米勒電機鮑米勒驅(qū)動器維修,
鮑米勒驅(qū)動BUM25-30/60-30-0001 鮑米勒BAUMULLER伺服驅(qū)動器維修,
鮑米勒DF30K-IEC71-DS 56-B2維修,
Baumuller鮑米勒伺服驅(qū)動器BUM618-12/18-31-R-0010-C010-SM維修,
鮑米勒伺服驅(qū)動器 BM4423-St1-01242-0311-7012維修,
鮑米勒 BUS21L-7.5/15-31-224 BUG2-60-31-B-209維修,


轉(zhuǎn)載請注明出處:上海仰光電子科技專業(yè)伺服驅(qū)動器維修,伺服電機維修
本文鏈接:http://www.sagreslocals.com/fuwu/Services_Show23636.htm
伺服驅(qū)動器維修 伺服電機維修  觸摸屏維修   變頻器維修


聯(lián)系方式:

電話:021-50157782
手機:13817011982 微信同號
郵箱:shygdzi@163.com
聯(lián)系人:張工
網(wǎng)址:http://www.sagreslocals.com
【 我們確保修好測試好給客戶。。!】

上一篇:金華市測試臺發(fā)那科觸摸屏A20B系列PWR燈不亮--維修售后點
下一篇:沒有了

最新相關(guān)內(nèi)容推薦:
 
RM新时代入口-首页